Medizin - Open Access LMU - Teil 15/22 Archiv
249 Episoden
1 minute
This paper reviews current knowledge on the role of the long-chain polyunsaturated fatty acids (LC-PUFA), docosahexaenoic acid (DHA, C22:6n-3) and arachidonic acid (AA, 20:4n-6), in maternal and term infant nutrition as well as infant development. Consensus recommendations and practice guidelines for health-care providers supported by the World Association of Perinatal Medicine, the Early Nutrition Academy, and the Child Health Foundation are provided. The fetus and neonate should receive LC-PUFA in amounts sufficient to support optimal visual and cognitive development. Moreover, the consumption of oils rich in n-3 LC-PUFA during pregnancy reduces the risk for early premature birth. Pregnant and lactating women should aim to achieve an average daily intake of at least 200 mg DHA. For healthy term infants, we recommend and fully endorse breastfeeding, which supplies preformed LC-PUFA, as the preferred method of feeding. When breastfeeding is not possible, we recommend use of an infant formula providing DHA at levels between 0.2 and 0.5 weight percent of total fat, and with the minimum amount of AA equivalent to the contents of DHA. Dietary LC-PUFA supply should continue after the first six months of life, but currently there is not sufficient information for quantitative recommendations.
1 minute
Background: Cancer antigen CA15-3 antigen is known as a valuable marker for the management of breast cancer. Methods: The analytical and clinical performance of the Access' BR Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA15-3 on the Elecsys(R) System (Roche Diagnostics). Results: Total imprecision (%CV) of the BR Monitor ranged between 5.5% and 11.7%, and inter-laboratory reproducibility between 3.4% and 5.1%. Linearity upon dilution showed a mean recovery of 98.5% (SD+/-9.1%). Endogenous interferents had no influence on BR Monitor levels (mean recoveries: hemoglobin 112%, bilirubin 111%, triglycerides 108%). There was no high-dose hook effect up to 13,540 kU/L. Clinical performance investigated in sera from 1811 individuals showed a general correlation between the Access BR Monitor and Elecsys CA15-3 (R = 0.797), with a slope of 1.383. CA15-3 serum levels, as measured by the BR Monitor, were low in healthy individuals (n = 267, median = 11.9 kU/L, 95th percentile = 23.5 kU/L), higher in individuals with various benign diseases (n = 549, medians = 11.3-15.6 kU/L, 95th percentiles = 21.6-54.6 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 11.2-22.8 kU/L, 95th percentiles = 30.0-429.7 kU/L). Best diagnostic accuracy for cancer detection against the relevant benign control group by the BR Monitor was found for locoregional and metastatic breast cancer, as well as for ovarian cancer {[}area under the curve (AUC) 0.619, 0.897 and 0.774]. Results for the reference CA15-3 assay were comparable (AUC 0.611, 0.887 and 0.818). Conclusions: The Access BR Monitor provides accurate methodological characteristics and demonstrates an analytical and clinical correlation with Elecsys CA15-3. Best diagnostic accuracy for the BR Monitor was found in breast and ovarian cancer. Our results also suggest a clinical value of the BR Monitor in other cancers.
1 minute
Background: Gastrointestinal cancer antigen CA19-9 is known as a valuable marker for the management of patients with pancreatic cancer. Methods: The analytical and clinical performance of the Access(R) GI Monitor assay (Beckman Coulter) was evaluated on the UniCel(R) Dxl 800 Immunoassay System at five different European sites and compared with a reference method, defined as CA19-9 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the GI Monitor ranged between 3.4% and 7.7%, and inter-laboratory reproducibility between 3.6% and 4.0%. Linearity upon dilution showed a mean recovery of 97.4% (SD+7.2%). Endogenous interferents had no influence on GI Monitor levels (mean recoveries: hemoglobin 103%, bilirubin 106%, triglycerides 106%). There was no high-dose hook effect up to 115,000 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access' GI Monitor and Elecsys CA19-9 (R = 0.959, slope = 1.004, intercept +0.17). GI Monitor serum levels were low in healthy individuals (n = 267, median = 6.0 kU/L, 95th percentile = 23.1 kU/L), higher in individuals with various benign diseases (n = 550, medians = 5.8-13.4 kU/L, 95th percentiles = 30.1-195.5 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 8.4-233.8 kU/L, 95th percentiles = 53.7-13,902 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the GI Monitor was found for pancreatic cancer {[}area under the curve (AUC) 0.83]. Results for the reference CA19-9 assay were comparable (AUC 0.85). Conclusions: The Access(R) GI Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with the Elecsys CA19-9. The GI Monitor shows the best diagnostic accuracy in pancreatic cancer. Our results also suggest a clinical value of the GI Monitor in other cancers.
1 minute
Background: Cancer antigen CA125 is known as a valuable marker for the management of ovarian cancer. Methods: The analytical and clinical performance of the Access OV Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA125 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the OV Monitor ranged between 3.1% and 8.8%, and inter-laboratory reproducibility between 4.7% and 5.0%. Linearity upon dilution showed a mean recovery of 100% (SD+8.1%). Endogenous interferents had no influence on OV Monitor levels (mean recoveries: hemoglobin 107%, bilirubin 103%, triglycericles 103%). There was no high-dose hook effect up to 27,193 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access OV Monitor and Elecsys CA125 (R = 0.982, slope = 0.921, intercept = + 1.951). OV Monitor serum levels were low in healthy individuals (n = 267, median = 9.7 kU/L, 95th percentile = 30.8 kU/L), higher in individuals with various benign diseases (n = 549, medians = 10.9-16.4 kU/L, 95th percentiles = 44.2-355 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians= 12.4-445 kU/L; 95th percentiles = 53.4-4664 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the OV Monitor was found for ovarian cancer {[}area under the curve (AUC) 0.898]. Results for the reference CA125 assay were comparable (AUC 0.899). Conclusions: The Access OV Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with Elecsys CA125. The best diagnostic accuracy for the OV Monitor was found in ovarian cancer. Our results also suggest a clinical value of the OV Monitor in other cancers.
1 minute
Background: The chemical inertness of hydroxyethyl starch (HES) might cause interferences of the colloid with a variety of laboratory tests. We aimed to evaluate potential influences of HES 130/0.4, the newest HES type, on several common hematology and clinical chemistry parameters. Methods and results: A convenient sample of 25 patients scheduled for rheological therapy with 500 mL 6% HES 130/0.4 was evaluated. Blood samples were drawn before and after colloid application. Comparing pre- and post-infusion values of a battery of laboratory tests (i.e., hematology and hemostasis parameters, electrolytes, enzymes, kidney and metabolic parameters, lipids, etc.) in time course, a median difference greater than the reference change value for a specific parameter was considered clinically relevant. Among all parameters tested, only serum amylase activity displayed a clinically relevant difference between pre- and post-infusion values (median increase of 85% due to HES administration). By applying in vitro experiments, we demonstrated that serum amylase values obtained in the samples diluted in a 1:1 ratio with HES 130/0.4 and in samples diluted in a 1:1 ratio with 0.9% NaCl displayed a negligible median difference of 3%. Conclusions: The in vivo effect of HES 130/0.4 administration on serum amylase activity observed in our study was pharmacological (real) in nature. With the exception of the influence of HES 130/0.4 on amylase activity, the effects of HES 130/0.4 on other parameters tested in this study can be interpreted as having no clinical relevance.
1 minute
Background: Allogeneic bone transplantation is at risk of infection, and established disinfection methods typically compromise bone quality. High hydrostatic pressure (HHP) is well established for disinfection in food technology, and also it does protect biomechanical and biological properties of bone. This study is the first investigation of HHP regarding disinfection of bone biopsies. Materials and methods: Bone biopsies of 34 patients with chronic infections were subjected to HHP and assessed for persisting bacterial growth. In series 1, bone biopsies were proceeded directly to HHP (10 min; maximal pressure P-max 600 MPa). In series 2, HHP was applied after 5-day incubation in growth media (10 min or 2 x 30 min; P-max 600 MPa). Furthermore, HHP-induced changes of bacterial morphology on artificially infected bone samples were evaluated by scanning electron microscopy (SEM). Results: For series 1, 71% of the bone samples were sterilised by HHP (n = 17), compared to 38% of the untreated control samples, which were obtained during the same surgery (n = 8). For series 2, after prior incubation, HHP disinfected 7% of the bone specimens (n = 55), all control samples showed bacterial growth (n = 33). Destruction of cell wall integrity of Gram-negative strains was observed by SEM. Conclusion: The effectiveness of HHP for bone disinfection should be improved by optimising treatment parameters. Infections with barosensitive Gram-negative bacteria or yeast might represent possible clinical indications.
1 minute
We retrospectively studied the single and combined diagnostic value of carcinoembryonic antigen (CEA), cytokeratin fragment 19 (CYFRA 21-1), neuron specific enolase (NSE) and pro-gastrin-releasing peptide (ProGRP), which were routinely analysed in patients with lung tumours of unknown origin at the time of admission to hospital. Inclusion criteria were the determination of CEA (AxSYM/Abbott), CYFRA 21-1 (ElecSys/Roche) and NSE (Kryptor/Brahms). We examined 1747 patients, where 1325 suffered from lung cancer (LC; small cell lung cancer, SCLC: n=194; non-small cell lung cancer, NSCLC: n = 1015; others: n = 116), 318 from benign lung diseases and 104 from lung metastases due to another primary malignancy. As ProGRP (ELISA ALSI/IBL) became available only recently, there are less data points of this marker. In total, 99.8% of LC patients released at least one of the four biomarkers (defined as values exceeding the median of healthy controls), and for the discrimination between benign disease (BID) and malignant lung disease each marker reached 100% tumour specificity at high levels (CEA: 20 ng/mL; CYFRA 21-1: 40 ng/mL; NSE: 45 ng/mL; ProGRP: 250 pg/mL). At a specificity of > 99%, ProGRP reached the highest diagnostic efficacy for SCLC with 57% true positive results, CEA had the highest capacity (17%) to detect malignant lung tumours in general and adenocarcinomas of the lung with 29%. CYFRA 21-1 was dominant for squamous cell carcinomas (12%). Combining the four markers leads with the prerequisite of high specificity (> 99%) to 50% true positives for malignant lung tumours, 44% for NSCLC, 36% for squamous cell carcinomas, 53% for adenocarcinomas, and 78% for SCLC, respectively. In cases of lung tumours of unknown origin, the combined use of CEA, CYFRA 21-1, NSE and ProGRP is useful for the differentiation between benign and primary or secondary malignant disease and suggests the assignment to histological subtypes.
1 minute
Tumor markers refer to all detectable and measurable analytes which are able to indicate a solid tumor or contribute to its characterization or judgment concerning tumor spread and therapy efficacy. Among the markers, humoral circulating tumor substances, such as precursors of normal antigens, ectopically produced hormones or enzymes, ontogenetic old reactivated antigens, hybridoma-defined mucins and cytokeratins are of special interest. Up to now, no tumor specific biomarker has been detected, all markers known so far are physiological components of blood; thus, their diagnostic capacity is more related to quantity than to quality. The tumor marker concentration depends on the tumor blood supply and reflects tumor mass and tumor spread as a sum of marker expression, synthesis, release, the catabolism of the organism, as well as the marker excretion. Changes in biomarker levels without correlation to tumor load can be due to impairment of the liver and kidney function or due to invasive diagnostic methods (endoscopy, biopsy, ureteral catheter) or due to acute reactions on treatment (surgery, radio-chemotherapy). Due to problems with standardization between assays from different producers measuring the same antigen, interpretation of biomarkers of single measurements, such as PSA (prostate specific antigen), must be performed using assay specific reference ranges and interpretation of serial measurements must be performed using the identical assay. The test result has to be indicated together with the assay used (kit and producer). Among the potential indications for tumor marker determinations, the early detection or screening of a tumor is unrealistic - except PSA in prostate cancer detection. In rare cases, biomarkers can be helpful in tumor localization (HTG (human thyreoglobuline), PSA) and support of primary diagnosis, the knowledge about their prognostic relevance is increasing, the most widely used indication is therapy control and follow-up care in context with medical imaging. Provided that markers are critically selected following the localization of the tumor, that serial determinations are performed using the identical assay and that the clinical question is relevant, tumor markers contribute to a significant degree to diagnosis, prognosis, therapy control and early detection of metastatic or recurrent disease. Especially in the field of diagnostic oncology, the quality of the investigator is significantly linked to the quality of the test result.
1 minute
Drug hypersensitivity reactions have to be tested to identify the culprit substance. The history includes the general information and specific data concerning used drugs, the classification and circumstances of the reaction. Skin tests are performed in all hypersensitivity reactions with allergic symptoms. Tests should be done between four weeks and six months after clearance of the symptoms by performing skin prick test, intradermal test, patch test or photopatch test. Validated tests for the detection of specific IgE antibodies in the serum are available for only few drugs, especially betalactam antibiotics. Other laboratory tests, e.g., the basophil activation test are done only in special cases. Provocation tests are indicated, if the culprit drug cannot be identified by the above mentioned tests. If possible, the evaluation of provocation tests should rely on objective parameters. The concluding assessment will be discussed with the patient and will be documented in an allergy pass.
1 minute
Serum levels of interleukin 6 (IL-6), procalcitonin (PCT), and C-reactive protein (CRP) were measured in 38 critically ill patients immediately after an increase in body temperature above 38.3 degrees C. Ten healthy controls were also included for comparison. The onset of fever was accompanied by elevated circulating levels of all the 3 markers in comparison to healthy control subjects. However, only IL-6 levels were significantly higher (p